Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T05CM01626
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/08/2005 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
09/07/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 16' OK-POP OUTS TOPPED OUT |
|
09/06/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 8' OK - OK TO GROUT 12' WHEN SPEC INSP CONFIRMS REMAINING VERTS IN PLACE |
|
09/01/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 4' AT WALL OK (STEM AND LIFT) |
|
08/30/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* WEST WALL TAPPED OUT |
|
08/26/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) TOP OF SOUTH WALL AND NORTH 1/2 OF WEST WALL |
|
08/23/2005 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* 1) RAINED OUT |
|
08/19/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 16' SOUTH AND WEST 2) I NEED TO SEE STAMPED PLAN REVIEW ON CANTILEVER? PLANS. ALSO STAMPED CALES FOR CANTILEVER NOTE: IF YOU START BUILDING IT IS AT YOUR OWN RISK!! |
|
08/16/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 16' SOUTH; 12' WEST WALL |
|
08/11/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 8' WEST WALL/ 12' SOUTH WALL |
|
08/10/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) L2 LINTEL AT A/9-10 2) CANTILEVERED LINTEL WITH BOND BEAM LAPS IN PROPER THIRDS AT BOTTOM AND TOP OF LINTEL PER DETAIL 13/S5 3) STIR UPS WITH 8" HOOK PLACED PER ENGINEER REQUEST IN LINE WITH BOND BEAM OK 4) RECALL FOR FINAL COURSE OF BLOCK WITH TOP BOND BEAM |
|
08/08/2005 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
08/05/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 4' WEST WALL OK 2) PLANS SHOW L4 CMU LINTEL AT A-1 MAGICALLY FLOATING IN AIR. I NEED A GOOD DETAIL FOR SIZE AND SHAPE (REDUCED LENGTH FROM ORIGINAL PLAN) FOR THIS CANTILEVERED LINTEL (STAMPED REVISION) |
|
08/03/2005 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 4' SOUTH WALL |