Permit: T05CM01612

Parcel: 14115008T

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T05CM01612

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
10/24/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
09/26/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :* INSULATE ALL HOT PIPING PER PLAN. COMPLETE COLD 1 1/4 SUPPLY PER PLAN AND FINISH OVERHEAD ALONG SOUTH & WEST WALL.
09/01/2005 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1) ALL UNDERGROUND OK PER REVISED PLAN
TEST TO ROOF OK ON ALL VENT STACKS
2) FINISH BRACING/SUPPORTING VENT STACKS
07/22/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PLANS HAVE BEEN APPROVED IN ERROR: ISOMETRIC SHOWS MOP SINK CONNECTED TO GREASE TRAP. THIS IS A VIOLATION OF UPC 1011.3. YOU MAY NOT TIE 2 FIXTURES TO SAME FLOW CONTROL AND FLOW CONTROL MUST BE IN A VISIBLE AND ACCESSIBLE LOCATION
2) WHY IS MOP SINK BEING CONSIDERED AS A GREASE GENERATING FIXTURE ?
3) VERIFY 3 COMPARTMENT SINK DOES NOT REQUIRE AN INDIRECT WASTE CONNECTION