Permit: T05CM01607

Parcel: 140382990

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/23/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/21/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) STRAP NON OVER LAPPING DBL TOP PLATE
2) CLIP KING STUDS
3) #3 HOLDOWNS NOT INSTALLED
4) 3 EACH D-10 TRUSSES MISSING BRACING
5) NO TRUSS DRAWINGS ON SITE
6) MIDDLE CROSS BRACE MISSING
7) O.S.B. ROOF PANELS NOT NAILED LOOSE
8) O.S.B. ROOF PANELS MUST SPAN THREE TRUSSES-TWO BAYS
9) O.S.B. RIPPERS MUST BE 12" WIDE OR SUPPORT EDGE