Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/23/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) LAST INSPECTION ITEM #2 TRUSS PROBLEM. NO TRUSS DRAWINGS ON SITE |
|
| 06/22/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MANY ROOF PANELS NOT NAILED EITHER SHINED OR MISSING STAPLES 2) B01E MISSING 5-9 BRACE |
|
| 06/21/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER JERRY |
|
| 06/17/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) B01B MISSING TRUSS BRACE 2) D-10 TRUSSES REQUIRE 6/5/13 BRACING 3) 3 PT ? TRUSS E02P NOT MID BEARING 4) MANY ROOF OSB PANELS LOOSE. NOT STAPLED 5) S.E. GABLE END TRUSS NOT CLIPPED TO POST, ALSO SOUTHWEST CORNER |
|
| 06/14/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NEED TRUSS DRAWINGS 2) SHIM REAR 3 PT. BEARING TRUSSES 3) LOOSE OSB ON ROOF 4) NAIL ALL DRAG STRUTS TO ROOF 6" ON CENTER 8D ? 5) SHEAR BOXES AT GARAGE TO HOUSE NOT NAILED TO ROOF PER DETAIL, LAYOUT PANELS EVERY OTHER BAY 6) STARTING AT THE ENDS OF THE SHEARWALL |