Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2006 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* CONNECTION TO DRAIN IS OK |
|
| 08/29/2006 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* - OK TO COVER SEWER PIPE - OK TO COVER WATER PIPE - PROVIDE TEST ON DRAIN CONNECTION ABS CEMENTED INTO CONCRETE TANK. |
|
| 08/28/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - 55 PSI ON WATER OK - CORRECT SLOPE AT VENT RISER AND ON SEWER PIPING 10'-20' S OF INTERCEPTOR. - PROVIDE WATER TEST ON SEWER - PROVIDE SHADING ON PIPING FROM DRAIN TO INTERCEPTORS. - TYPE OF INTERCEPTOR & DRAIN OK |
|
| 08/09/2006 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PROVIDE DOCUMENTATION ALLOWING THE TYPE OF DRAIN AND INTERCEPTOR USED IS OK, BECAUSE THE ONES INSTALLED ARE DIFFERENT THAN SPECIFIED. - ALL NON-METALLIC PIPING BELOW GRADE REQUIRES - TRACER WIRES OF THE APPROPRIATE COLOR - INSTALL BLUE 18 GAUGE TRACER WIRE ON WATER, SECURE AT EVERY 8' AND AT 12" ABOVE GRADE. - USE APPROPRIATE FITTINGS TO MAKE 45 DEG. CHANGE OF DIRECTION, PROVIDE PRESSURE GAUGE FOR TEST. - INSTALL GREEN TRACER WIRE ON DRAIN PIPING, SECURE AT 8' INTERVALS AND TERMINATE WIRE IN CLEANOUT COVERS. - LEAVE A MESSAGE W/YOUR PHONE # WHEN MAKING INSPECTION REQUEST SO I CAN LET YOU KNOW WHEN I AM COMING SO THAT YOU CAN REMOVE PLATES FOR INSPECTION. - EXPOSED PIPING ON WALL SHALL BE CAST IRON AND VENT SHALL TERMINATE 6" ABOVE SIDE WALL. - POINT OF VENT SHALL BE ABOVE THE FLOW LINE OF SEWER - ROLL VENT FITTING UP TO A MINIMUM OF 45 DEG. TO MEET CODE. - HAVE ELECTRICAL INSPECTION ADDED TO PERMIT CARD CALL 791-5550 EXT. 1158 |