Inspection History Details
Inspection Status: Denied
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/27/2005 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* ELECTRICIAN TO CHECK ALL ELECTRICAL WORK 1. POST TO BEAM CONNECTION NOT CORRECT HARDWARE 2. SERV. EQUIP. CU#14 WIRE PROTECTED BY 20 AMP OVER CURRENT DEYCE 3. NO MORE THAN 6 SWITCHES ALLOWED WITHOUT A MAIN DISCONNECT 4. STEP REQUIRED AT BEDROOM TO LIVING ROOM 5. EXPOSE SEWER CONNECTION. 6. CLEAN OUT @ BATH. 7. EXPOSE FOOTING AT PORCH FOOTERS 8. GFI @ BATH NEEDS TO BE ON OWN CIRCUIT. 9. EXPOSE H2O LINES @ TRANISITIONS EXTERIOR 10. 2'X6' NOT FULL BEARING ON WALL PROVIDE LEDGES 11. PROVIDE BLOCKING @ PORCH 12. PORCH UNSAFE DUE TO NON BEARING RAFTERS |