Permit: T05CM01585

Parcel: 132091050


Addresses:

2902 E RICKEY VISTA

Inspection Status: Denied

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
06/27/2005 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
ELECTRICIAN TO CHECK ALL ELECTRICAL WORK
1. POST TO BEAM CONNECTION NOT CORRECT HARDWARE
2. SERV. EQUIP. CU#14 WIRE PROTECTED BY 20 AMP OVER CURRENT DEYCE
3. NO MORE THAN 6 SWITCHES ALLOWED WITHOUT A MAIN DISCONNECT
4. STEP REQUIRED AT BEDROOM TO LIVING ROOM
5. EXPOSE SEWER CONNECTION.
6. CLEAN OUT @ BATH.
7. EXPOSE FOOTING AT PORCH FOOTERS
8. GFI @ BATH NEEDS TO BE ON OWN CIRCUIT.
9. EXPOSE H2O LINES @ TRANISITIONS EXTERIOR
10. 2'X6' NOT FULL BEARING ON WALL PROVIDE LEDGES
11. PROVIDE BLOCKING @ PORCH
12. PORCH UNSAFE DUE TO NON BEARING RAFTERS