Permit: T05CM01576


Addresses:

4401 E SENECA ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
04/29/2005 ELECTRIC - FINAL Approved IVRS - Inspection :*
04/21/2005 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MAINTAIN POSITIVE FALL CONDENSATE PIPING DRAIN THROUGHOUT
2) SECURE GAS PIPE AT UNIT (ATTIC)
3) MORE DUCTWORK SO AS SHUT OFF VALVE IS ACCESSIBLE
4) NEED PLATFORM TO EXTEND TO FRONT OF UNIT
5) NEED TYPE B VENT DBL WALL THROUGH ROOF WITH 1" CLEARANCE MAINTAINED TO COMBUSTIBLE
6) REMOVE TAPE USE SCREWS ON FLUE PIPE
7) TRAP AND VENT CONDENSATE LINES
8) MUST BE ABLE TO REMOVE COVER ON FRONT OF ANTI (ATTIC). NO COMBUSTIBLES IN FROM OF FIRE BOX
9) INSTALL SHEET METAL IN FROM OF FIRE BOX AREA AFTER INSTALLING APPROVED PLATFORM
10) STOPPED INSPECTION
04/19/2005 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO PLANS/PERMIT VISIBLE
2) EXTERIOR CONDENSATE DRAIN TO GROUND AND SUPPLY DRYWELL FOR DRAINAGE
3) NEED ACCESS INSIDE ATTIC TO CHECK UNIT INSIDE BE SURE TO HAVE ALTERNATE OVERFLOW DRAIN TO EXTERIOR AND DRAIN PAU; ETC...
4) STOPPED INSPECTION