Inspection History: SHEET ROCK NAILING

Permit Number - T05CM01570

Inspection Description - SHEET ROCK NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
01/10/2008 SHEET ROCK NAILING Approved IVRS - Inspection :*
12/17/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
REPAIR ELEV. SHAFT WHERE SCAFFOLD REMOVED
11/27/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
10/16/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
1. ALL BUT 1ST FLOOR LAUNDRY, ELEV. LOBBY, TRASH ROOM
2. ABOVE CEILING FIRESTOP IN CORRIDORS INCOMPLETE
3. UEU305 IS 1 HOUR WALL FOR CORRIDORS BASICALLY WOOD FRAME WITH GYPSUM ON BOTH SIDES - DEFINITION OF FIRE BARRIER REQUIRES THEY EXTEND FROM FLOOR BELOW TO DECK ABOVE THEREFORE GYPSUM IS REQUIRED ON BOTH SIDE OF CORRIDOR WALLS FLOOR TO DECK. IT MAY NOT TERMINATED ON ONE SIDE AT CEILING.
10/09/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
WITHOUT ARCHITECT DETAILING CORRIDOR ASSEMBLY UL U305 THEN A CORRIDOR MUST HAVE WALL TO ECK NOT CEILING CHECK SEC U305 L528 SYSTEM 4
10/01/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
1ST FLOOR PHASE 2
09/24/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
2ND FLOOR GUESTROOMS OK PHASE 1, 2, 3
2ND FLOOR CORRIDOR EXCEPT PHASE 3 OK
N/WEST STAIR OK
N/EAST STAIR OK
09/18/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
1. 1ST FLOOR PHASE 1 - GUESTROOMS FIRESTOP OK
2. 1ST FLOOR PHASE 2 WEST END OK
09/17/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
09/13/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
2ND FLOOR 2ND PHASE; 1 NEED TO SEE FIRE STOP BEFORE TAPING AROUND PENETRATIONS
09/11/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
1ST FLOOR 1ST PHASE/2ND FLOOR 2ND PHASE
RECALL BEFORE TAPING
09/05/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
2ND FLOOR DWELLING UNITS OK EXCEPT DO NOT TAPE FIREWALL PENETRATIONS.
08/31/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
PROGRESS OK -- CALL WHEN FLOOR DONE
08/28/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
1ST LAYER LIDS & 2ND FLOOR OK
WEST WING
08/10/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
1) PHASE 3 1ST LAYER LIDS 1ST AND 2ND FLOOR
08/01/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
FIRST LAYER OF DRYWALL INSTALLATION ON FIRST AND SECOND LEVEL FLOOR PHASE 2 ON CORRIDOR.
07/26/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
THIS INSPECTION COVERS THE FOLLOWING AREAS 1ST FLOOR LEVEL PHASE I
SECOND LAYER, 2ND FLOOR LEVEL FIRST LAYER
07/24/2007 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
THIS INSPECTION COVERS NAILING FIRST LAYER OF FIRE RESISTANT PROTECTION ON CORRIDOR PHASE 2