Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/13/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 12/12/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ACCESSIBLE SIGNAGE TO BE ON WALL, LATCH SIDE OF DOOR 2. MAX. 5 LBS. PULL ALLOWED ON DOORS. |
|
| 12/11/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NOTE: PROVIDE INSPECTION HISTORY FOR 1030 ROOF NAILING CORRECTION LEFT ON 10/17/06 1090 BUILDING FINAL |
|
| 10/17/2006 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* BEFORE YOU CALL FOR FINAL PLEASE CHECK FOLLOWING 1. DO NOT USE KRAFT FACED INSULATION BATTS ABOVE CEILING. 2. TOILET FLUSH HANDLES MUST BE ON WIDE SIDE OF ROOM. 3. YOU NEED IMPERMEABLE HARD WALL SURFACE WITHIN 2' OF W.C 4. WATER CLOSETS TO BE 16"-18" FROM SIDE WALL. |