Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM01543
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/07/2005 | FRAMING | Approved | IVRS - Inspection :* 1) 00035 APPROVED BY F. GREER ON 6/27/05 |
|
06/24/2005 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) GARAGE P-1 SHEARWALL REQUIRES HILTI PINS AT 8" ON CENTER PER SHEET SL1 2) 1" CLEARANCE REQUIRED FROM WATER HEATER "B" VENT TO COMBUSTIBLE 3) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 4) A35 CLIPS AT GARGE P-1 MUST BE CLIPPED TO TRUSS NOT TO NAILER 5) PEX PLUMBING NOT ALLOWED WITHIN 12" OF RECESSED LIGHTS 6) STOPPED INSPECTION-TO MANY ITEMS |