Date Description Inspector Results Comments
06/18/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
RECEIVED BACTERIA REPORT FOR POTABLE WATER SYSTEM
05/28/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. TERMINATE EXTERIOR CLEANOUTS TO GRADE WITH APPROVED GAS TIGHT CAPS
2. COMPLETE INSULATION ON ALL HOT WATER PIPING
3. MAKE ALL FIXTURES WATER TIGHT AT WALLS & FLOORS
4. PROVIDE A MEANS TO CONTROL HOT WATER TEMPERATURE AT PUBLIC USE LAVS NOT TO EXCEED 110 DEG. BESIDES THE WATER HEATER
5. ALL CLEANOUTS & FLOOR DRAINS TO BE FLUSH WITH FINISH FLOOR
6. SEPTIC ACCESS MANHOLE COVERS TO BE TO FINISH GRADE

BACTERIA REPORT ON SITE
02/29/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CLOSET FLANGES OK