Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T05CM01519
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/17/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
10/15/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST THRU ROOF PARTIAL APPROVAL DWV EXCEPT GANG RESTROOMS, REQUIRE PER PLAN 3" VENTING OVERHEAD FOR WOMENS AND CORRECT DIRECTIONAL VENT FITTING (DOUBLE ELL) OK 2 SEPARATE FITTINGS. SUPPORT OVERHEAD HORIZONTAL AT 6' INTERVALS AND CHANGES OF ELEVATION & DIRECTION. WATER PIPING FROM STUB OUT OF BUILDING THRU BUILDING OK SHALL INSULATE HOT & HOT RETURN PIPING BEFORE COVERING |