Permit: T05CM01505

Parcel: 111061310

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
06/23/2005 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection OK FOR SHEET ROCK. CORRECTIONS HAVE BEEN MADE. BE SURE TO USE A ROOF JACK WHERE CONDENSATE PIPE PENETRATES THE ROOF
06/21/2005 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999* YOU CANNOT TERMINATE THE CONDENSATE INTO THE TAILPIECE ON THE WASHER BOX STANDPIPE. USE THE KNOCKOUT IN THE TOP OF THE WASHER BOX & TERMINATE 1" ABOVE THE KNOCKOUT INSIDE THE WASHER BOX. IF YOU DON'T DO IT RIGHT THIS TIME, YOU WILL BE CHARGED A RE INSPECTION FEE . RECALL FOR INSPECTION
06/20/2005 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999* REMOVE THE SCREWS FROM THE DRYER VENT EXTENSION IN UNIT 1. PROVIDE A CONDENSATE DRAIN LINE. NOTE: CONDENSAE CANNOT DRIP OUT OF A SCUPPER, CANNOT CONNECT TO A SEWER VENT. YOU CAN GO TO THE WASHER BOX,LAV. TAILPIECE, OR DIRT. RECALL FOR INSPECTION.
06/17/2005 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) EXTEND DRYER VENT OUT OF WALL FAR ENOUGH TO CORRECT THE DRYER TO. PROVIDE A PLATE STRAP ON DRYER VENTS. REMOVE SCREEN FROM T -TOP. 2) STRAP EXHAUST FAN DUCTS AT PENETRATION THRU ROOF. PROVIDE A SCREW IN BATTON OF CONNECTION TO FANS. 3) INSULATE ALL EXPOSED SHEET METAL ON SIDEWALK REGISTER BOXES. 4) EXTEND RETURN AIR DUCTS DOWN TO CEILING. 5) PROVIDE A CONDENSATE DRAIN LINE TO AN APPROVED LOCATION.
06/16/2005 MECHANICAL - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*