Inspection History Details
Inspection Status: Denied
Inspection History: ROOF NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/07/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 4X4 POSTS SHALL BE ELEVATED 1" FROM CONCRETE ROOF RAFTERS CANNOT BE ATTACHED TO BARGE RAFTER A BEARING WALL ON POST AND BEAM CONSTRUCTION IS REQ'D ROOF SHALL BE NAILED TO ROOF RAFTERS 6" ON EDGES AND 12" IN FIELD - ON ADDITION BUILT WITHOUT PERMITS EXPOSE ALL ELECTRICAL WIRING AND FRAMING AT BOTH BEARING POINT EXPOSE FOUNDATION AT CORNERS AND MID POINT |
|
| 09/01/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLAN CALLS FOR 4X6 POST WITH 4X8 BEAM RESTING ON TOP. FOR NAILING ON ROOF 6" ON DEUAMS? AND 12 ON FIELD. PROVIDE PROPER NAILS ON JOIST HANGERS PROVIDE REVISION FOR PORCH |
|
| 08/15/2005 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection :* 1) EXISTING ADDITION ON NORTH SIDE: SECURE OUTLETS AND LABEL BREAKERS 2) WEATHER PROOF COVERS ON EAST EXT. LIGHT FIXTURES 3) RE-SUBMIT PLAN TO PLAN REVIEW REGARDING PORFH ROOF CONNECTION TO EXISTING HOUSE |