Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/20/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/14/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) SEAL GAS CHASE, HAVE DETAIL PUT ON PLAN 2) DO BEARING PTS REQUIRED WEB STIFFNERS AT ALL BEARING PTS. 3) DWV TEST ON BOTH FLOORS 4) H20 TEST 25 POUNDS GAUGE 5) FINISH STUCCO 6) HOW IS GAS LINE LARGER THAN 1/2 IDENTIFIED 7) TRUSSES AT REAR PORCH 3 PT BEARING, MISSED INTERIOR PT., DRAWINGS IN TRUSS CALC'S NOT THE TRUSS INSTALLED, RAT RUN ? |
|
| 07/05/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) NEED GAS CHASE DETAIL 2) MOVE PEX 12" AWAY FROM LIGHT CANS 3) PROTECT GAS PIPING CLOSER THAN 3" TO EDGE 4) REPAIR WIRING 5) TIE EXT. SHEAR TO BOTTOM CHORDS 6) USE MINIMUM SIZE NAIL IN TJI HANGERS 16D INTO FACE AND 12D INTO JOIST 7) NEED DETAIL OF SLOPED TJI TO TOP PLATE CONNECTION 8) NEED POTABLE AND DWV H20 TESTS 9) RAISE VTRS 1' ABOVE FRESH AIR INTAKE 10) FLAT VENT 2ND FLOOR, TO COME OFF UPPER 1/3 OF HORIZONTAL DRAIN |