Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM01480

Parcel: 12213032B


Addresses:

1155 N BRYANT AV

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/21/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
NOTES LEFT FROM INSPECTOR RANDY O'HAVER ON 6/8/05 FOR 1030-ROOF NAILING INSPECTION RE:1) PLAN SHOWS 2" X 8" RAFTERS-2" X 6" EXISTS
2) PLAN SHOWS 4" X 10" RIDGE BEAM-2' X 8' EXISTS
3) PLAN CALLS FOR 3' X 3" PAD AT 4" X 6" POST FTG.-NON EVIDENT
4) STOPPED INSPECTION
-------------------------------------------------------------------------------------------------
1) ITEM 01030 NOT REQUIRED PER PAPERWORK TURNED IN BY INSPECTOR E. DURAZO