Permit: T05CM01460

Parcel: 113093310

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/20/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/15/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH LAST INSPECTION
2) EXPOSE LINE UNDERGROUND
3) NAIL PROTECT 220 LINE TOP PLATE
4) BLOCK REGISTERS 3-SIDES
5) MISSING NUTS SOLE PLATES/MISSING AB PLATE ENDS
6) FIRE BLOCK ALL DROPPED CEILING
07/07/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FLUSH NAIL ALL BRACED WALL PANELS/NAILS PRETRUDE
2) EXTERIOR HOLDOWNS MUST BE FASTENED TO DBL STUDS NO BLOCKING
3) NOT EXPOSED
07/06/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) LOOSE SHEAR AT S.E CORNER. 2) SOME CLIPS NOT NAILED.
06/30/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CLIP AND STRAP TRUSSES, STUDS AND HEADERS
2) NAIL BIRD BOARDS, RIDGE BLOCKS AND FASCIA
3) NEED ALTERNATE H.D. AT WEST WINDOW FOR INTERMEDIATES