Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/20/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/15/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH LAST INSPECTION 2) EXPOSE LINE UNDERGROUND 3) NAIL PROTECT 220 LINE TOP PLATE 4) BLOCK REGISTERS 3-SIDES 5) MISSING NUTS SOLE PLATES/MISSING AB PLATE ENDS 6) FIRE BLOCK ALL DROPPED CEILING |
|
| 07/07/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FLUSH NAIL ALL BRACED WALL PANELS/NAILS PRETRUDE 2) EXTERIOR HOLDOWNS MUST BE FASTENED TO DBL STUDS NO BLOCKING 3) NOT EXPOSED |
|
| 07/06/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LOOSE SHEAR AT S.E CORNER. 2) SOME CLIPS NOT NAILED. |
|
| 06/30/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CLIP AND STRAP TRUSSES, STUDS AND HEADERS 2) NAIL BIRD BOARDS, RIDGE BLOCKS AND FASCIA 3) NEED ALTERNATE H.D. AT WEST WINDOW FOR INTERMEDIATES |