Permit: T05CM01430

Parcel: 140377340


Addresses:

6905 S WINGBOW DR

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/07/2005 BUILDING - FINAL Approved IVRS - Inspection :*
09/01/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WIRE DAMAGED IN ELECTRICSERVICE PANEL DUE TO OVER TORQUE OF GROUNDS AND NEUTRALS
REPAIR ALL WIRES AND RETORQUE ALL LUGGS TO SPECIFICATIONS?
2) INSTALL POST TENSION TAPS AT WATER SERVICE ENTRANCE
3) PAINT PVC PIPES EXPOSED TO SUNLIGHT
4) 4" CLEARANCE REQUIRED BETWEEN STUCCO WEEP SCREED AND SOIL
5) INSTALL INSULATION ON OUTSIDE AC COPPER LINES
6) NO POWER TO OUTSIDE GFCI CIRCUITS
9) NO STUCCO OR INSULATION CONTRACTS