Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/18/2005 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1) SUPPORTS ADDED OK 2) CLOSET FLANGES OK |
|
| 07/07/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) ABS DWV WATER TEST THRU ROOF OK 2) ADD SUPPORT AS NEEDED |
|
| 06/23/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) HORIZONTAL VENTING BELOW THE FLOOD LEVEL RIM OF FIXTURE LIMITED TO STRUCTURAL CONDITIONS ONLY. 2) ALL CHANGES TO THE PLAN MUST BE AT LEAST REDLINED FOR INSPECTION. 3) WET VENTING LIMITED TO VERTICAL DRAINAGE PIPING | |
| 06/23/2005 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) STRUCTURAL CONDITIONS PRECLUDE CONVENTIONAL INSTALLATION. PLAN IS RED LINED TO REFLECT INSTALLATION 2) OK TO COVER 3) GREASE WASTE CONNECTED OK 4) PLEASE CALL PRE-POUR |
|
| 06/22/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) NO SUITE NUMBER POSTED. UNABLE TO LOCATE PLAN OR PERMIT. NOBODY ON SITE. | |
| 06/20/2005 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |