Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM01389
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/31/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/23/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) DBL 2 X POSTS REQUIRED UNDER GIRDER TRUSS PER PLAN 4 EACH 2) TRUSSES NOT BEARING PER PLAN 3) 14/DT1 BLOCKING PANELS MISSING 4) RAT RUNS NOT INSTALLED 5) ROOF NOT INSPECTED |
|
05/19/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) INSTALL RAT RUNS 2) ROOF NAILING INCOMPLETE 3) SHIM ALL 3 PT. BEARING 4) MISSING P.A. STRAP AND PATIO PORCH HARDWARE |