Permit: T05CM01387

Parcel: 110051620

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/07/2005 BUILDING - FINAL Approved IVRS - Inspection :*
05/26/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ALL WORK COMPLETED WITHOUT INSPECTION
2) WILL NEED TO DIG DOWN VERTICALLY TO VERIFY MINIMUM 12" CONCRETE BELOW GRADE POST FTGS
3) NEED TO OPEN UP 2 X 6 BEARING AT EXIST. HOUSE TO VERIFY CONNECTIONS
4) NEED APPROVED CEILING FAN BOXES (ELECTRICAL)
5) GROUND ALL METAL ELECTRIC BOXES
6) SECURE ELECTRIC WITHIN 12" ALL BOXES
7) MAINTAIN MINIMUM 1 1/4" CLEARANCE FROM EDGE
8) RAFTER HOLES DRILLED ROMEX OR INSTALL METAL BANG PLATE PROTECTION ON TOP OF RAFTER
9) ANY ROMEX BELOW 8' TO BE IN CONDUIT
10) VERIFY ELECTRIC LOAD ON 2 LIGHTS AND 2 FANS DOES NOT OVERLOAD LIGHT CIRCUIT TIED IN AT EXTERIOR LIGHT BOX
11) USE APPROVED BOXES-CONNECTIONS ALL ELECTRIC
12) ROOF PLYWOOD COVERED WITHOUT INSPECTION-REMOVE
13) 3 AREAS TO INSPECT PLYWOOD