Inspection History Details
Permit: T05CM01381
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/25/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 01/24/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LOW VOLTAGE TRANSFORMER NOT ALLOWED IN BEDROOM CLOSET |
|
| 01/23/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOTE OF RECORD: OUTLET UNDER BREAKFAST BAR BLANKED OUT AND P2 SHEARWALL AT FAMILY ROOM-NOTE A 9 1/2 X 11 PIECE HAS BEEN CUT OUT FOR CABLE, HIGH SPEED INTERNET AND SURROUND SOUND 2) WILL NEED ACCESS TO JACUZZI MOTOR 3) BLOWN INSULATION NOT PER CODE 4) FAU'S, SECONDARY PANS FULL OF CONSTRUCTION DEBRIS 5) REST OF HOUSE OK |
|
| 01/20/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CONDENSATE LINE MISSING 90 DEGREE ELBOW 2) POST TENSION TAG MISSING 3) NEED ACCESS TO BWV 4) NO POWER TO GFCI DOWNSTAIRS BATH OR UPSTAIRS 5) GFCI IN UPSTAIRS HALL BATH ADDED AND ROMEX NOT SECURED WITHIN 8" FROM BOX 6) STOPPED INSPECTION 7) HOUSE NOT WALKED BY SUPERINTENDENT |