Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T05CM01373
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/16/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
09/27/2005 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE 6" MINIMUM FLOOD RIM TO CRITICAL LEVEL MARK ON VACCUM BREAKER TUBE OF FLUSH VALVE IN MENS RESTROOM |
|
07/26/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CALL IN ALL UNAPPROVED INSPECTIONS (2) READ AND COMPLY WITH ALL NOTES LEFT FROM 7/14/05 INSPECTION 2) TERMINATION OF CONDENSATE AT WOMEN'S LAV AREA SHALL BE GRAVITY DRAIN TO TERMINATION |
|
07/14/2005 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FLOOR DRAINS TO BE FLUSH WITH FINISH FLOOR TO AVOID TRIPPING HAZARD. 2) FLUSH VALVES REQUIRE 6" MINIMUM DISTANCE FROM CRITICAL LEVEL MARK ON VACUUM BREAKER TUBE TO FLOOD RIM OF FIXTURE. 3) HANDICAP FLUSH VALVE HANDLES ON STOOLS TO BE ON WIDE SIDE OF RESTOOM AREA. |