Permit: T05CM01373

Parcel: 13414001K


Addresses:

7820 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05CM01373

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/16/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
09/27/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE 6" MINIMUM FLOOD RIM TO CRITICAL LEVEL MARK ON VACCUM BREAKER TUBE OF FLUSH VALVE IN MENS RESTROOM
07/26/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CALL IN ALL UNAPPROVED INSPECTIONS (2) READ AND COMPLY WITH ALL NOTES LEFT FROM 7/14/05 INSPECTION
2) TERMINATION OF CONDENSATE AT WOMEN'S LAV AREA SHALL BE GRAVITY DRAIN TO TERMINATION
07/14/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) FLOOR DRAINS TO BE FLUSH WITH FINISH FLOOR TO AVOID TRIPPING HAZARD. 2) FLUSH VALVES REQUIRE 6" MINIMUM DISTANCE FROM CRITICAL LEVEL MARK ON VACUUM BREAKER TUBE TO FLOOD RIM OF FIXTURE. 3) HANDICAP FLUSH VALVE HANDLES ON STOOLS TO BE ON WIDE SIDE OF RESTOOM AREA.