Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T05CM01364
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/02/2006 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection :* - FEMALE PLASTIC ADAPTORS ARE PROHIBITED USE PVC MAKE THREADS INTO BUILDING SERVICES - PROVIDE BLUE TRACER WIRE ON ALL NON-METALLIC PIPING - EXPOSE UPSTREAM CONNECTION AT IRR ASSEMBLY. PROVIDE CERT. |
|
07/31/2006 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* | |
02/14/2006 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* HCS CONNECTION OK TO COVER HCS REQUIRES AN IRON BODY CLEAN OUT COVER CONCRETED IN AT GRADE AND A CONTINUITY TEST AFTER BACKFILL AND METALLIC TAPE. SDR BUILDING SEWER OK |