Permit: T05CM01364

Parcel: 10406011E


Addresses:

2075 W GARDNER LN


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T05CM01364

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/07/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
1. PLUMBING FINAL OK
OK FOR LETTER OF COMPLETION
S.T.O.I
01/31/2007 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OVERHEAD COPPER OK
CLOSET FLANGES OK
OK TO COVER ALL AREAS
01/19/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. MAKE SURE YOUR TRUCKS DO NOT BLOCK EGRESS THRU THE PARKING LOT.
2. CALL IN AND HAVE APPROVED ALL REQUIRED INSPECTIONS.
12/18/2006 PLUMBING - INTERMEDIATE Partial Approval 1. IS 5 2003 UPC NO FEMALE ABS THREADS IN INACCESSIBLE LOCATION -- REMOVE BLAKE TEE.
2. NEED TO SEE CLOSET FLANGE UNIT #1
12/13/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
NOTE #1: HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP.

NOTE #2: DO NOT USE RECTOR SEAL ON ABS!!!
12/02/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
UNITS #4 & #5 OK TO COVER WALLS
10/30/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. UNIT #10 & #11 CORRECTIONS MADE OK
OK TO COVER
2. CLOSET FLANGES TO BE SCREWED TO THE FLOOR
10/26/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
UNIT 10 & 11
PROVIDE CORRECT SLOPE ON VENT AND VENT FITTINGS.
1 1/2" TRAP ARM REQUIRED FOR LAVS

I BELIEVE THAT A TEST ON EVERY JOINT IS NECESSARY ON THIS JOB. FILL ENTIRE SYSTEM.
10/25/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
10/20/2006 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
UNIT #1
WIER OF TRAP SHALL NOT BE ABOVE POINT OF VENT.
LAV TRAP ARM SHALL BE 1 1/2"
CLEANOUT SHALL BE ACCESSIBLE.

CHECK YOUR WATER SUPPLY STUB OUT LOCATION FOR WC

UNIT #10
DOUBLE FIXTURE FITTING REQUIRED AT DOUBLE FIXTURE CONNECTION.
REVENT ABOVE 42"
INSTALL SAFETY PLATES
INSTALL SAN T AT REVENT IN PROPER DIRECTION OF PLAN
CLEAN OUT SHALL BE ACCESSIBLE
SUPPORT OVERHEAD COPPER AT CHANGE OF ELEVATION
09/18/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. COPPER SUPPLY OVERHEAD FOR EASTSIDE COMPLETE.
2. UNIT 12 OK TO COVER WALLS.
09/01/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. UNIT #2 & #3 ABS THRU ROOF OK
COPPER OK
OK TO COVER WALLS
NEED TO SEE CLOSET FLANGES
08/31/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. SUPPORT HORIZONTAL OVERHEAD PIPE
2. FILL ABS SYSTEM WITH WATER
3. NEED TO SEE CLOSET FLANGES
07/13/2006 PLUMBING - INTERMEDIATE Not ready for Inspection 1. EAST UNIT PLUMBING WALL OK TO COVER.
NO TEST ON ABS
SUPPORT VERTICAL ABS
NEED TO SEE CLOSET FLANGE
07/10/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. EAST UNIT, PLUMBING WALL, OK TO COVER TO OVERHEAD
01/23/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*OK TO POUR NEXT SECTION