Permit: T05CM01358

Parcel: 112031720


Addresses:

2810 E MCKENZIE ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/07/2005 FRAMING Approved IVRS - Inspection :*
1) REINSPECT
06/03/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) YOU NEED A CLEANOUT FOR WASHER DRAIN USE A BLAKE TEE
2) YOU HAVE DRILLED 2 X 6 RAFTER AT GAS PIPE TO CLOSE TO EDGE (LEFT A HAND OUT FOR YOU TO SEE) INSTALL BLOCKS ON EITHER SIDE OF HOLE FROM RAFTER DRILLED TO RAFTER WEST OF, DRILLED RAFTER BLKS TO BEAR ON 2 X 6 WALL TOP PLATE
3) EXTEND 4 X 4 SWITCH BOX AT VENNER FLUSH WITH BRICK
4) INSTALL VERTICAL BACKING AT TUB SIDES
5) YOU HAVE 3/4" GAS LINE FROM METER (EXISTING) INTO HOUSE, WHERE ARE YOU TIED INTO GAS LINE FOR DRYER ? GAS LINE NEEDS TO BE SIZED BY YOUR PLUMBER LEAVE PIPE DIAGRAM ON SITE FOR INSPECTION
6) WHERE WAS MECH TAPPED INTO ?
7) WHERE WAS H20 TAPPED INTO ?
8) MECHANICAL NOT ON JOB CARD, DID YOU BUY A MECH PERMIT ?
05/27/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/20/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FRAMING WILL BE APPROVED WHEN ALL TRADES ARE COMPLETE