Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/07/2005 | FRAMING | Approved | IVRS - Inspection :* 1) REINSPECT |
|
| 06/03/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) YOU NEED A CLEANOUT FOR WASHER DRAIN USE A BLAKE TEE 2) YOU HAVE DRILLED 2 X 6 RAFTER AT GAS PIPE TO CLOSE TO EDGE (LEFT A HAND OUT FOR YOU TO SEE) INSTALL BLOCKS ON EITHER SIDE OF HOLE FROM RAFTER DRILLED TO RAFTER WEST OF, DRILLED RAFTER BLKS TO BEAR ON 2 X 6 WALL TOP PLATE 3) EXTEND 4 X 4 SWITCH BOX AT VENNER FLUSH WITH BRICK 4) INSTALL VERTICAL BACKING AT TUB SIDES 5) YOU HAVE 3/4" GAS LINE FROM METER (EXISTING) INTO HOUSE, WHERE ARE YOU TIED INTO GAS LINE FOR DRYER ? GAS LINE NEEDS TO BE SIZED BY YOUR PLUMBER LEAVE PIPE DIAGRAM ON SITE FOR INSPECTION 6) WHERE WAS MECH TAPPED INTO ? 7) WHERE WAS H20 TAPPED INTO ? 8) MECHANICAL NOT ON JOB CARD, DID YOU BUY A MECH PERMIT ? |
|
| 05/27/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 05/20/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FRAMING WILL BE APPROVED WHEN ALL TRADES ARE COMPLETE |