Permit: T05CM01340


Addresses:

1553 W BEANTREE LN


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T05CM01340

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/31/2005 BUILDING - FINAL Approved IVRS - Inspection :*
1) NONE OF RECORD STEVE JACOBS AND H. PEDROZA TESTED THE ARC FAULTS NEAUTRALS TRIPPED.
RESIET ARC FAULTS AT PANEL, TRUE READING
08/30/2005 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) POST TENSION TAG MISSING
2) PAINT PVC LINES
3) NO POWER TO EXTERIOR GFCI, FRONT GFCI BURIED IN WALL
4) COACH LIGHT AT GARAGE NO SHEETHING INTO ELEC BOX, MIN 1/4" REQUIRED
5) SERVICE OUTLET ROMIEX? IN ATTIC TIGHT AND MOVE AWAY FROM ATTIC ACCESS
6) FAV SRC PAN FULL OF CONSTRUCTION DIEBDI?
7) ARC FAULT TESTER SHOWS SHARED NEUTRALS
08/29/2005 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
08/26/2005 BUILDING - FINAL Cancelled CANCELLED PER PAPERWORK TURNED IN BY INSPECTOR F. GREER