Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/24/2006 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/08/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) PENDING ALTERNATE HOLDOWNS AT KITCHEN 2) HPAD HOLDOWNS AT KITCHEN WINDOW AND KITCHEN DOOR WILL NEED RETROFIT ALTERNATE HOLDOWNS 3) HPAD MUST BE NAILED TO 2 CONTINOUS STUDS-NO BLOCKS 4) OK TO INSTALL STUCCO MESH-ALTERNATIVES INSPECTED AT INTERMEDIATES |
|
| 11/02/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NAIL OFF PLYWOOD ROOF, AT SOFFIT AREA, INTO SOLID BLOCKING 2) NAIL OFF WALL SHEATHING AT SOUTH DOOR AREA AND EAST WALL-SOUTH END-1ST FLOOR FOR BOTH 3) NEED ROOF TRUSS CALC'S WERE TRUSSES DESIGNED FOR SHINGLE OR TILE ROOF ? 4) NOTE: IN THE FUTURE, CODE REQUIRES 3/8" OSB SHEARWALLS TO BE INSTALLED HORIZONTALLY |