Date Description Inspector Results Comments
07/27/2005 FRAMING Approved IVRS - Inspection :*
07/25/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CHANGE OUT HEADER GARAGE MAN DOOR
2) BANG PLATES REAR BATH
3) HANGER AT TRUSS TO GIRDER-HANGER CUT
4) SHEAR TRANSFER
07/18/2005 FRAMING Partial Approval IVRS - Inspection :*
1) ADD OSB AT ATTIC ACCESS
2) ADD H/D REAR SLIDER
3) COMPLETE MESH AND WEEP SCREED SOUTH SIDE GARAGE
4) EXTEND GROUND TO GAS LINE