Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM01310
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/25/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/02/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) # 2 ABOVE NEED ENGINEERING FOR MISSED GUSSET PLATE FRONT BEDROOM, CHECK AT INTERMEDIATE. | |
05/31/2005 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO LOAD ROOF 2) FRONT BEDROOM TRUSS 3) CHANGE OUT HANGER NAILS SMALL GIRDER BED. FRONT HUS26=1302 LB LOAD, HANGER CARRIES 3260 LBS |