Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T05CM01309
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/03/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/01/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) ROOF NAIL-OK 2) NEED ALL 2ND FLOOR TIED TO FIRST FLOOR 3) USE LTP4'S OR A35F TO TIE, NOT RSP4'S 4) NAIL BELLY BAND AND SHEAR AT FLOOR TO FLOOR PER PLAN OR USE ALTERNATE 302/5.4 5) MISSING 3 P.A. STRAPS WEST, EAST AND SOUTH |