Permit: T05CM01306

Parcel: 141017220

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/23/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/17/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) MISSING BLOCKING AND NAILING FRONT HIP AND VALLEY
2) FRONT AND REAR COLUMNS, STUDS NOT TIED TO BOTTOM PLATES
3) POST TENSION STAMP IN CONCRETE MISSING
4) INSTALL VERTICAL LEG AT HIP JOINT TO RIDGE AND VERTICAL LEG AT MAXIMUM 48" ON CENTER ON 2 X 4 TOP CHORD FOR SUPPORT