Inspection History Details
Permit: T05CM01299
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/01/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/30/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STUCCO LATH NOT COMPLETE AT BACK PORCH 2) BUILT UP POST REQUIRED UNDER GLUE LAM BEAM NORTH END 3) 1" CLEARANCE REQUIRED TO COMBUSTABLE MATERIAL (ABS PLASTIC) 4) FIRE STOP REQUIRES 2 LAYERS OF 1/2" OSB 5) FIRE STOP W/H VENT CHASE AT 2ND FLOOR CEILING 6) FIRE STOP EAST CHASE AT GARAGE 7) 2ND FLOOR P.1 SHEAR WALL SILL PLATE NOT NAILED PER PLAN 8) FIRE STOP 2ND FLOOR PENETRATING 9) ANCHOR WALLS 10) HOLD DOWNS MISSING, SEE PLAN 11) LEAK AT DWV STACK WYE 12) CLIP BEARING POSTS TO PLATE 13) STRAINED / MIS ALIGNED DOWN CONNECTION AT KITCHEN DIRTY ARM 14) AC WIRES OUT OF WALE? |