Permit: T05CM01299

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/25/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/20/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) WIND BRACE MUST BE INSTALLED IN OPPOSITE DIRECTIONS BOTH FLOORS
2) P-3 SHEAR REQUIRES ENDS AND EDGES BLOCKED AND NAILED AT 3" ON CENTER
3) NAIL DBL STUDS ON SHEARWALL AT EDGE NAIL SCHEDULE
4) P-1 SHEARWALL NOT NAILED
5) GARAGE GLB REQUIRES 4-2 X 4 POSTS-AND CLIPPED
6) STOPPED INSPECTION-TO MANY ITEMS
07/19/2005 EXT METAL CLIPS/EXT SHEATHING Cancelled 9:22 AM-CANCEL PER PHONE CALL RECEIVED FROM TIM OF K.B. HOMES #907-6040
07/19/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*