Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ABOVE CEILING
Permit Number - T05CM01287
Inspection Description - PLUMBING - ABOVE CEILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/23/2005 | PLUMBING - ABOVE CEILING | Approved | IVRS - Inspection :* | |
11/16/2005 | PLUMBING - ABOVE CEILING | Partial Approval | IVRS - Inspection :* 1) ALL DRAINS FROM BACKFLOW DEVICES TO TERMINATE WITH 90 DEGREE DOWN AT FLOOR SINKS 2) REPAIR LEAKS AT DRAINS ON BACKFLOW THAT ARE DUMPING WATER 3) PERM CAP OLD DRAIN IN RESTROOM 4) DRAINS FROM FOOT SPA'S TO BE DIRECTIONAL FITTING WITH NO RESTRICTION AND GRAVITY DRAIN 5) CHAIR #4 TO HAVE GRAVITY DRAIN AND TERMINATE AT DOWNWARD ANGLE WITH 1" AIR GAP 6) SUPPORT VENT ABOVE CEILING IN BREAK ROOM 7) DRAINS FROM BACKFLOWS TO GRAVITY DRAIN AND BE SUPPORTED AT 4' INTERVALS |