Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/28/2005 | FRAMING | Approved | IVRS - Inspection :* SEE ITEM OF 7/22/05 INSPECTION - OK TO INSULATE & DRY IN |
|
| 07/27/2005 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 07/26/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 07/22/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HAVE ENGINEERING LETTER DATED 7/11/05 APPROVED BY CITY FOR THIS ADDRESS 2) PROVIDE LSI CERTIFICATION OF 3000 PSI CONCRETE IN REPAIR 3) NO DWV WATER TEST 4) SHIM HEADERS TO DBL TOP PLATES (SAGGING) 5) DUCT RESTRICTED BR 3 |
|
| 07/20/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO DWV WATER TEST 2) FIRE/SHEAR BLOCK MISSING GARAGE/LAUNDRY 3) SHIM HEADER TO TRIMMERS 4) PEX CANNOT BE WITHIN 12" OF CAN LIGHTS 5) AC DUCT MISSING M. BATH 6) PLUMBING OUT OF WALL M. LAV 7) W/C REQUIRES 15" TO WALLS 8) PROVIDE 1/2" TRUSS CLEARANCE 9) LAV DIRTY ARM CANNOT EXCEED 1 1/2" 10) RED HEADS LOOSE 11) DUCTS RESTRICTED 12) GAS LINE MUST BE WITHIN 36" OF FURANCE 13) HAVE ENGINEERING CITY OF TUCSON APPROVAL |