Permit: T05CM01257

Parcel: 140383450

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
07/19/2005 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
07/15/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO DWV WATER TEST
2) 1/2" CLEARANCE REQUIRED BETWEEN NON BEARING WALLS AND SCISSOR TRUSSES
3) REPLACE OVERNOTCHED STUDS
4) OK TO INSULATE
07/14/2005 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
07/13/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 1 1/2" TRAP ARM MAY NOT EXCEED 42" LENGTH
07/07/2005 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*