Permit: T05CM01246

Parcel: 115040870


Addresses:

625 E MABEL ST #02


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T05CM01246

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/09/2006 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/07/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL ROMEX CONNECTOR H20 HEATER ELECTRIC
2) INSTALL ROMEX IN FLEX CONDUIT
3) SECURE GALVANIZED PIPE TO WALL EXTERIOR H20 LINE
4) PAINT EXPOSED VENTS ON ROOF
5) BOLT DOWN AND SEAL AROUND TOILET
6) CUT SEWER CELANOUT TO GRADE
7) INSTALL ANTI-SIPHON HOSE BIBS
8) NEED INSULATION CERTIFICATE
9) INSTALL ARC FAULTS BEDROOMS AND SMOKE DETECTORS
10) UNCOVER SEWER AND H20 LINES FOR VERIFICATION
11) STOPPED INSPECTION