Permit: T05CM01235

Parcel: 140377910

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/10/2005 FRAMING Approved IVRS - Inspection :*
08/09/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPAIR TO CONDENSATE MADE WITH AN APPARENT MODIFIED LISTED FITTING WHICH IS NOT APPROVED. PROVIDE A LIKE UNUSED COUPLING AND THE UPC LISTING FOR THAT PART
08/08/2005 FRAMING Partial Approval IVRS - Inspection :*
1) HOLE IN CONDENSATE LINE-UP STAIRS
08/04/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
HOLE IN CONDENSATE LINE M/BR
FIRE STOP BR2
OK TO INSULATE
08/01/2005 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) LATH MISSING WIRE AT FRONT
2) W/H T & P LINE MUST EXHAUST 6" ABOVE SIDE WALK
3) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE
4) HTT16 HOLDOWN NOT INSTALLED GARAGE P-3 SHEARWALL
5) ANCHOR BOLTS SPACING NOT PER PLAN ON SHEARWALLS
6) SUPPORT HORIZONTAL DWV WAT 4' ON CENTER WITH APPROVED SUPPORT
7) 1" CLEARANCE REQUIRED BETWEEN WATER HEATER B VENT AND ABS PLUMBING
8) TIMBER STRAND HANGER BY POWDER ROOM BENT TO LOOK LIKE SUPPORT. REPLACE HANGER
9) STOPPED INSPECTION-TO MANY ITEMS
10) SUPERINTENDENT TO INSURE HOUSE IS COMPLETE TO CODE AND PLAN PRIOR TO NEXT INSPECTION