Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/18/2005 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 11/14/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEMS 2 AND 5 FROM 11/7/05 NOT COMPLIED WITH 2) CAULK TOILET POWDER ROOM AND KITCHEN SINK 3) STAIR HAND RAIL REQUIRES 1 1/8" CLEARANCE TO WALL ONLY 1 3/16" EXISTS 4) NEED FURNACE INSTALLATION MANUAL |
|
| 11/07/2005 | BUILDING - FINAL | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) NO SIDE WALK TRIP HAZARD 2) OUTSIDE HOSE BIBS REQUIRE NON REMOVABLE ANTI-SIPHON VALVES 3) PROVIDE LATEX PAINT UV PROTECTION TO PLASTIC PIPES 4) T & P LINE MUST EXHAUST BETWEEN 6'-18" OF GRADE 5) PROVIDE 5 PERCENT GRADE 5 FEET FROM POST TENSION SLAB 6) REMOVE UNTREATED WOOD FROM SOIL 7) 4" CLEARANCE REQUIRED BETWEEN WEEP SCREED AND SOIL 8) GARAGE PERSONNEL MUST BE SELF CLOSING LATCHING 9) STOPPED INSPECTION-TO MANY ITEMS |