Permit: T05CM01185

Parcel: 13311008A


Addresses:

7151 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T05CM01185

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/26/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
LOWE'S - LIGHTING DIFF - WAS TO BE REDONE
02/20/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
02/16/2007 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
02/02/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
There is no plan or job inspection card on site.| 925*
1) NO PLANS/PERMITS OR PERSONEL ON SITE
07/12/2006 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
WAITING ON CERTIFICATION FOR LIGHTING PER SECTION 16 OUTDOOR LIGHTING CODE
01/27/2006 ELECTRIC - FINAL Partial Approval OK FOR TEMP C/O
01/24/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) OK ALL POLE BASE MAKE-UP
2) FINAL WILL BE SUBJECT TO OUTDOOR LIGHTING CERTIFICATION
01/06/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*OK INTERIOR OF STORE ALL SHELL RELATED ELECTRIC AND GARDEN CENTER.
WILL NEED PAPERWORK FOR CERTIFICATION OF OUTDOOR LIGHTING AS REQUIRED
01/04/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
01/03/2006 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*OK TO OCCUPY OFFICES, TRAINING ROOMS, DATA ROOMS EXCEPT AS NOTED. OK TO TCO FOR STOCKING ONLY
12/30/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*SCREW TERMINATIONS TO USE THERMAN ENDS WITH STRANDED CONDUCTOR
BOXES MORE THAN 1/4" FROM BOX TO SURFACE TO USE AN APPROVED EXTENDER RINGS
BOND BUSHINGS NEEDED AT CONCENTRIC KNOCK OUTS OVER 250 V OR E??
TIGHTEN FITTINGS AND SUPPORT CONDUIT FOR SECURITY
12/29/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*