Permit: T05CM01185

Parcel: 13311008A


Addresses:

7151 E SPEEDWAY BL


Inspection Status: Approved

Inspection History: ELECTRIC - UNDERGROUND

Permit Number - T05CM01185

Inspection Description - ELECTRIC - UNDERGROUND

Inspection Status - Approved

Date Description Inspector Results Comments
01/18/2006 ELECTRIC - UNDERGROUND Approved IVRS - Inspection :*
01/04/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1. SUPPORT SEAL TITE UP OFF OF GROUND OUTSIDE AT UNIT
OK GARDEN CENTER
OK POLE BASES & CONDUITS
01/03/2006 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
12/29/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
OK TO TILE
1. FILL UNUSED OPENINGS IN FACE PLATE
2. BOX CRUSHER DISCONNECT: LABEL, CORRECTLY IDENTIFY CONDUCTORS PLEASE VERIFY LISTING AND LABEL
3. SUPPORT CONDUIT CHARGERS
4. SUPPORT CONDUITS AS PER CODE GARDEN CENTER
5. PLEASE VERIFY LISTING AND LABELS ON ALL EQUIPMENT
6. FINISH FLOODLIGHTS GARDEN CENTER.
12/28/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*OK PVC CONDUIT POLE TO POLE AS MARKED
OK POLE BASES AS MARKED
12/20/2005 ELECTRIC - UNDERGROUND Not ready for Inspection IVRS - Inspection :*
12/19/2005 ELECTRIC - UNDERGROUND Not ready for Inspection IVRS - Inspection :*
12/14/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :* OK TO STAND POLES- OK HEAD MAKE UP
OK PVC POLE TO POLE AS MARKED
OK 1 POLE BASE AS MARKED
12/13/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
OK PANEL CP2
OK 2 POLE BASES AS MARKED
OK PVC CONDUIT POLE TO POLE AS MARKED
OK ALL ROOFTOP UNITS
12/12/2005 ELECTRIC - UNDERGROUND Not ready for Inspection IVRS - Inspection :*
ALL FRONT GRID AREAS
1. VDV CABELING TO BE SUPPORTED 6' INTERVALS AND INDEPENDENTLY 725.6, 760.6, 800.6, 300.11
2. EXIT LIGHTS TO HAVE SUPPORT WIRE - FINISH EXIT LIGHTS IN FRONT - OK 2X4 LIGHTING
12/06/2005 ELECTRIC - UNDERGROUND Not ready for Inspection IVRS - Inspection :*
12/03/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
12/02/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
12/01/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
11/30/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
11/29/2005 ELECTRIC - UNDERGROUND Not ready for Inspection IVRS - Inspection :*
11/22/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
11/17/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*OK 6-1" PVC CONDUIT 10' FROM POLE OUT TO DRIVE AT GARDEN CENTER
11/07/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :$POWER BOX SOLUTIONS
POWER LINK BY SQD
11/01/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*4 SOUTH GARDEN CENTER POLE BASES CONDUIT @ 24" DEPTH APROX 80' OF CONDUIT RESCHEDULE POLE BASES
10/31/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
10/04/2005 ELECTRIC - UNDERGROUND Not ready for Inspection IVRS - Inspection :*
10/02/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*OK PVC CONDUITS FRONT OFFICES
09/09/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK 2-4" PVC UNDER FOOTING-PHONE
09/07/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK PVC CONDUITS UNDER ELECTRIC ROOM
08/22/2005 ELECTRIC - UNDERGROUND Partial Approval IVRS - Inspection :*
1) OK PVC CONDUITS FROM ELECTRIC ROOM 1 TO ELECTRIC ROOM 2 AND PHONE ROOM