Permit: T05CM01166

Parcel: 140441030


Addresses:

8020 S FARMHILLS PL

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
08/05/2005 ROOF NAILING Approved IVRS - Inspection :*
08/02/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSTALL 2 X 4-16" ON CENTER OSB SHEAR AT GABLE ENDS
2) DETAIL 2/4 NOT PER PLAN (2 X 4 BLOCKING 1ST 2 BAYS TOP AND BOTTOM GABLE END AND ST 22 ACCROSS TOP OF SHEATHING
07/28/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE TRUSS BRALING ON D-3 TRUSS AT PTA AND TRUSS D-1, D-5, D-4
2. 1/2" CLEARANCE REQUIRED BETWEEN BOTTOM CHORD OF TRUSSES AND NON BEARING WALLS BELOW.
3. TRUSS DRAWINGS MUST BE APPROVED BY CITY OF TUCSON
4. SOUTH SHEAR WALL D.S. B PANELS MUST EXTEND TO ROOF DOCK PER 2/4
5. PROVIDE KNEE BRACING AT 4' O.C. PER TRUSS ENGINEERING ASCE-7
07/26/2005 ROOF NAILING Not ready for Inspection IVRS - Inspection :*
07/25/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TRUSS DRAWINGS DO NOT MATCH HOUSE
2) ROOF NOT INSPECTED