Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2005 | ROOF NAILING | Approved | IVRS - Inspection :* | |
| 08/02/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL 2 X 4-16" ON CENTER OSB SHEAR AT GABLE ENDS 2) DETAIL 2/4 NOT PER PLAN (2 X 4 BLOCKING 1ST 2 BAYS TOP AND BOTTOM GABLE END AND ST 22 ACCROSS TOP OF SHEATHING |
|
| 07/28/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE TRUSS BRALING ON D-3 TRUSS AT PTA AND TRUSS D-1, D-5, D-4 2. 1/2" CLEARANCE REQUIRED BETWEEN BOTTOM CHORD OF TRUSSES AND NON BEARING WALLS BELOW. 3. TRUSS DRAWINGS MUST BE APPROVED BY CITY OF TUCSON 4. SOUTH SHEAR WALL D.S. B PANELS MUST EXTEND TO ROOF DOCK PER 2/4 5. PROVIDE KNEE BRACING AT 4' O.C. PER TRUSS ENGINEERING ASCE-7 |
|
| 07/26/2005 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection :* | |
| 07/25/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TRUSS DRAWINGS DO NOT MATCH HOUSE 2) ROOF NOT INSPECTED |