Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM01137

Parcel: 121092890

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
04/14/2006 PLUMBING - INTERMEDIATE Approved CLOSET FLANGES ARE REQUIRED TO BE SECURELY FASTENED TO FLOOR WITH CORROSION RESISTANT FASTENERS.
04/11/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
OVERHEAD WATERLINE OK
REMOVE CONCEALED GEM GAP.
PROVIDE A PERM CAP ON 3" CLEANOUT RISER IN WALL
PROVIDE BACKING FOR MOP SINK FAUCET
MOP SINK FAUCET WILL REQUIRE NON-FERROUS PIPE NIPPLES
AT INSTALLATION.
OK TO COVER AFTER COMPLETING ABOVE CORRECTIONS.
CLOSET FLANGES NOT INSTALLED.
04/10/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
CALL MATT 275-0425
04/03/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*