Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05CM01118

Parcel: 141017310

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T05CM01118

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/22/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) OK TO LOAD ROOF
04/10/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NEED TRUSS DRAWINGS
2) OK TO DRY IN ROOF AND WALLS
04/06/2005 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) NEED TRUSS DRAWINGS
2) SHEAR 2ND FLOOR NORTH WALL WRONG LOCATION
3) NEED RETRO P.A. STRAP
04/05/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) MISSED 4'-0" SHEAR PANEL 2ND FLOOR
2) BLOCK CRICKET BOTH ENDS ROOF
3) SHIM 3 PT BEARING FLOOR TRUSSES
4) H2.5 AT GARAGE FRONT ROOF TO WALL
5) NAIL OFF ALL EXTERIOR SHEATHING
6) NEED RETRO P.A. AT EAST SHEAR
7) CHECK 4 PT AT FRONT ENTRY
8) NEED TRUSS DRAWINGS FOR 2188 ELEV. "C"
04/04/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) SEE LAST INSPECTION
03/31/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NOT READY SEE LAST INSPECTION
03/30/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :* NOT READY WORK INCOMPLETE. ( STAPLES TO BE AT ) = 4"OC & 8" O.C
03/29/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
03/28/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NO PLANS/PERMIT ON SITE
2) INCOMPLETE
3) NO LADDER