Inspection History Details
Permit: T05CM01110
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/14/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/10/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1. (LATH) EVERYWHERE THERE IS AN (N) PAINTED ON LATH THERE ARE NAILS MISSING. 2. PARTIAL PENDING LATH |
|
| 11/03/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLAN/PERMIT |
|
| 10/03/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LATH MISSING STAPLES AND SEAL ALL PENETRATIONS 2) PROVIDE TRUSS REVISION 3) ROMEX AT KITCHEN BELOW CEILING LINE 4) NAIL PROTECT DRYER VENT 5) F3A TRUSS REPAIR ? |
|
| 09/13/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE 2X6 CONTINUOUS STRONGBACK ATTACHED TO VERTICAL WEB, SEE TRUSS CALCS 2) FIRE BLOCK WINDOW CHASE 2ND FLOOR SOUTH 3) NAIL PROTECT DRYER VENT, ELEC ROMEX 4) SEE ITEMS 2, 5-11 INSP DID 9/1/5 5) FLOOR TRUSS AT STAIR ARE REPAIRED |
|
| 09/01/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TEAL M1 PENETRATIONS FROM 1ST TO 2ND FLOOR 2) FIRE BLOCK CHASE AT KITCHEN 3) COMPLY WITH DETAIL 10SD4 AS PER PAGE S4 AND 11 SD4 4) MISSING BLCOKING PER DETAIL 3SD2 5) COMPLY WITH DETAIL 50 AD3 6) FIRE BLOCK MECH CHASE 7) SINGLE WALL IN ATTIC NOT ALLOWED 8) TRUSS CLIP REMOVED SOUTH WEST 9) FIRE BLOCK B-VENT CHASE 10) NAIL PROTECT ELECTRIC AT SOUTH EAST B/R 11) SECURE ROMEX AT KITCHEN CEILING 12) HORIZONTAL RUNS FOR WATER LINES MUST HAVE 1 1/2 CLEARANCE FROM BOTTOM OF TRUSS 13) DWV'S OK STOPPED INSP |
|
| 08/25/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* CANCELLED ON SITE BY (BRUNO) KBH |