Permit: T05CM01109


Addresses:

1559 W BEANTREE LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM01109

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/12/2005 FRAMING Approved IVRS - Inspection :*
07/11/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GAS TEST FAILED
3) 2 X 6 STUDS CUT AT KITCHEN SHEARWALL
07/08/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CHECK FRAYED ROMEX AT HALL 2ND FLOOR RIGHT SIDE OF CAN LIGHT
2) EXHAUST FAN AT LAUNDRY NOT COMPLETE
3) GROUND PANCAKE BOX AT MASTER BATH
4) GAS TEST FAILED
07/01/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GAS TEST FAILED
2) BLOCK CONCEALLED SPACE AT NORTH BEDROOM
3) BLOCK FRESH AIR AT TOP OF STAIRS
4) SEE LAST INSPECTION
5) NAIL PROTECT ELECTRIC UPSTAIRS
6) CLIP LANDING
7) SHIM 3 POINTS BEARING F-TRUSSES
06/28/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COACH LIGHT METAL BOX NOT GROUNDED
2) REAR LIGHT METAL BOX NOT GROUNDED
3) NO TEST ON DWV'S
4) BLOCK ALL MECHANICAL 3-SIDES
5) REPAIR SHEAR WALL AT KITCHEN
6) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR
7) LANDING LEDGER SEPERATING FROM STUDS
8) STOPPED INSPECTION
06/24/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED ON SITE BY BRUNO (KBH)