Permit: T05CM01108


Addresses:

1571 W BEANTREE LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T05CM01108

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/20/2005 FRAMING Approved IVRS - Inspection :*
11/09/2005 FRAMING Partial Approval IVRS - Inspection :*
1) PARTIAL PENDING F-7 AND F-4 CITY APPROVAL
2) OK TO INSULATE
11/03/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SEE LAST INSPECTION AND NO TRUSS CALC'S
09/20/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FIRE BLOCK CHASE IN GARAGE
2) 3 POINT BEARING TRUSSES NOT BEARING
3) TOP CORD OF FLOOR TRUSS CUT 2 BAYS OVER FROM CONDENSOR LINES
4) FIRE BLOCK STRINGER AND COMPLY WITH STAIR DETAILS
5) FIRE BLOCK MECH CHASE
6) HTT16 MISSING AT GARAGE WALL
09/15/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RETRO HD AT GARAGE SHEER
2) REPAIR SHEER PANEL AT STAIRWAY LANDING
3) REPLACE BLOCK AT INTERIOR SHEER
4) STAPLE ROMEX 6" FROM BOX SOUTH MASTER WALL
5) FIRESTOP VENT CHASE AT MASTER BATH
6) FIRESTOP CONDENSER LINES
7) REMOVE BLOCKS UNDER TRUSSES AT MASTER BEDROOM
8) FIRE BLOCK/STOP GARAGE GABLE AT NW BEDROOM
09/12/2005 FRAMING Cancelled IVRS - RI canceled
09/09/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LSL IN GARAGE DAMAGED
2) MOVE ELEC WIRES AWAY FROM GUSSETT PLATES
3) ELEC BOX IN B/R DOWNSTAIRS NOT INSTALLED
4) NAIL PROTECT ELEC WITHIN 1 1/4" FROM EDGE OF STUD
5) COMPLY WITH STAIR DETAILS
6) ATH HANGER NOT NAILED
7) STOPPED INSP
8) NEXT FAILURE WILL REST IN A RE-FEE
09/06/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
8) PROTECT WIRES FROM METAL TRUSS GUSSET IN DOWN BED
9) STRAP NON-OVERLAPPED TOP PLATES IN MID-1ST FLOOR BEARING WALL
10) BANG PLATE A/C WIRES IN KIT
11) FHA CUT FLOOR TRUSS AT A/C LINES
12) FIRE STOP TUB OPENING
13) PROTECT PEX FROM GUSSETS
14) SHIM HEADERS WHERE NEEDED
15) INSTALL H.D.S
STOPPED INSP AFTER 1ST FLOOR
08/19/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NOT STAPLES PER CODE
2) NAIL PROTECT PLUMBING WITHIN 1 1/2 FROM EDGE OF STUD
3) LSL IN GARAGE MODIFIED
4) NO TEST ON DWV
5) STUDS MISSING AT HALL BAT WALL
6) OVERSPAN AT INTERIOR BEARING WALL/CLIPS ? NAILS
7) PLUMBERS TAPE NOT ALLOWED TO SPT. ABS.
STOPPED INSP.