Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T05CM01108
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/20/2005 | FRAMING | Approved | IVRS - Inspection :* | |
11/09/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PARTIAL PENDING F-7 AND F-4 CITY APPROVAL 2) OK TO INSULATE |
|
11/03/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEE LAST INSPECTION AND NO TRUSS CALC'S |
|
09/20/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FIRE BLOCK CHASE IN GARAGE 2) 3 POINT BEARING TRUSSES NOT BEARING 3) TOP CORD OF FLOOR TRUSS CUT 2 BAYS OVER FROM CONDENSOR LINES 4) FIRE BLOCK STRINGER AND COMPLY WITH STAIR DETAILS 5) FIRE BLOCK MECH CHASE 6) HTT16 MISSING AT GARAGE WALL |
|
09/15/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RETRO HD AT GARAGE SHEER 2) REPAIR SHEER PANEL AT STAIRWAY LANDING 3) REPLACE BLOCK AT INTERIOR SHEER 4) STAPLE ROMEX 6" FROM BOX SOUTH MASTER WALL 5) FIRESTOP VENT CHASE AT MASTER BATH 6) FIRESTOP CONDENSER LINES 7) REMOVE BLOCKS UNDER TRUSSES AT MASTER BEDROOM 8) FIRE BLOCK/STOP GARAGE GABLE AT NW BEDROOM |
|
09/12/2005 | FRAMING | Cancelled | IVRS - RI canceled | |
09/09/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) LSL IN GARAGE DAMAGED 2) MOVE ELEC WIRES AWAY FROM GUSSETT PLATES 3) ELEC BOX IN B/R DOWNSTAIRS NOT INSTALLED 4) NAIL PROTECT ELEC WITHIN 1 1/4" FROM EDGE OF STUD 5) COMPLY WITH STAIR DETAILS 6) ATH HANGER NOT NAILED 7) STOPPED INSP 8) NEXT FAILURE WILL REST IN A RE-FEE |
|
09/06/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 8) PROTECT WIRES FROM METAL TRUSS GUSSET IN DOWN BED 9) STRAP NON-OVERLAPPED TOP PLATES IN MID-1ST FLOOR BEARING WALL 10) BANG PLATE A/C WIRES IN KIT 11) FHA CUT FLOOR TRUSS AT A/C LINES 12) FIRE STOP TUB OPENING 13) PROTECT PEX FROM GUSSETS 14) SHIM HEADERS WHERE NEEDED 15) INSTALL H.D.S STOPPED INSP AFTER 1ST FLOOR |
|
08/19/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOT STAPLES PER CODE 2) NAIL PROTECT PLUMBING WITHIN 1 1/2 FROM EDGE OF STUD 3) LSL IN GARAGE MODIFIED 4) NO TEST ON DWV 5) STUDS MISSING AT HALL BAT WALL 6) OVERSPAN AT INTERIOR BEARING WALL/CLIPS ? NAILS 7) PLUMBERS TAPE NOT ALLOWED TO SPT. ABS. STOPPED INSP. |