Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/19/2005 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/18/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OSB ON ROOF MUST SPAN 2 BAYS 2) OSB EDGE MUST HAVE 1/8" CLEARANCE 3) NAIL PROTECT PLUMBING 4) STRAP PLUMBING FROM OUTSIDE DBL TOP PLATE 5) REPLACE OVER NOTCHED STUD BEHIND TUB |
|
| 07/15/2005 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEARWALLS/HOLDOWNS MISSING 2) WIND BRACING EXCEEDS MAXIMUM 25' OF RUN 3) STAPLES TO BE FLUSH WITH O.S.B. 4) PLAN CALLS FOR NAILS ROOF O.S.B. INTO 2 X BLOCKING AT BEARING 5) STRAP EXTERIOR BOTTOM PLATES AT PLUMBING CUTS 6) STOPPED INSPECTION |
|
| 07/06/2005 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
| 07/05/2005 | EXT METAL CLIPS/EXT SHEATHING | Cancelled | CANCELLED PER ROB OF RICHMOND AMERICAN HOMES 237-7204 |