Permit: T05CM01079

Parcel: 137294430

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/19/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/18/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OSB ON ROOF MUST SPAN 2 BAYS
2) OSB EDGE MUST HAVE 1/8" CLEARANCE
3) NAIL PROTECT PLUMBING
4) STRAP PLUMBING FROM OUTSIDE DBL TOP PLATE
5) REPLACE OVER NOTCHED STUD BEHIND TUB
07/15/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEARWALLS/HOLDOWNS MISSING
2) WIND BRACING EXCEEDS MAXIMUM 25' OF RUN
3) STAPLES TO BE FLUSH WITH O.S.B.
4) PLAN CALLS FOR NAILS ROOF O.S.B. INTO 2 X BLOCKING AT BEARING
5) STRAP EXTERIOR BOTTOM PLATES AT PLUMBING CUTS
6) STOPPED INSPECTION
07/06/2005 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
07/05/2005 EXT METAL CLIPS/EXT SHEATHING Cancelled CANCELLED PER ROB OF RICHMOND AMERICAN HOMES 237-7204