Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05CM01078

Parcel: 137294600

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
04/25/2005 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
04/21/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BRACE NORTH WEST MISSING NAILS
2) NAIL PROTECT PLUMBING AND COPPER LINES FROM OUTSIDE
3) STRAP CORNERS THAT ARE NOT CABIN TIED
4) DBL TOP PLATE ABOVE ENTRY HEADER NOT STAGGERED
5) NAIL SHEAR WHERE SHINERS SHOW
6) PROVIDE 1/8" GAP ON ALL EDGES
04/19/2005 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REPLACE CRIPPLES AT BATH WINDOW AND OVERSPAN
2) WIND BRACE SOUTH WEST SHORT
3) NAIL PROTECT PLUMBING FROM OUTSIDE
4) AHD 84 HOLDOWN MISSING WASHER AND NUTS
5) LADDER FOR ROOF ACCESS NOT SECURED
6) TRUSSES NOT BRACED PER CALC'S